Ethernet Relay Modules

LEO WR 8 Channel Web Relay Module

0 views May 11, 2026 vidya 0

Introduction

Sl.No.SKUDescriptionRelay TypeOperating temperature
1NLEWR008ALEO WR 8 Channel Web Relay Module - WR8ASPST-40 ℃ to 85 ℃
2NLEWR008A-24LEO WR 8 Channel Web Relay Module - WR8A-24SPST-40 ℃ to 85 ℃
3NLEWR008BLEO WR 8 Channel Web Relay Module - WR8BSPDT-40 ℃ to 85 ℃
4NLEWR008B-24LEO WR 8 Channel Web Relay Module - WR8B-24SPDT-40 ℃ to 85 ℃

LEO_WR8A_001.png

Note: In this document, “LEO WR8” refers to the LEO WR 8 Channel Web Relay Module.

The Numato Lab LEO WR 8 Channel Web Relay Module is a compact, network-enabled controller designed for remote control and monitoring of electrical and electronic devices.

The LEO WR8 provides 8 relay channels and high-voltage digital inputs supporting up to 24 V, with Ethernet and 2.4 GHz Wi-Fi connectivity.

The module supports multiple communication methods depending on the network interface:

  • Ethernet: Web interface, REST API, and Telnet
  • Wi-Fi: Web interface, REST API, and MQTT/MQTTS

The MQTT/MQTTS support allows the LEO WR8 to connect to MQTT-compatible cloud platforms and IoT services. Once connected, these platforms can be used to remotely monitor the device and control its relays, enabling integration with cloud-based automation systems.

With its flexible connectivity and easy-to-use interfaces, the LEO WR8 is suitable for industrial automation, IoT applications, remote equipment control, testing, and smart automation systems. Users can operate the device through the web interface or integrate it into custom applications using REST API, Telnet, or MQTT/MQTTS.

Applications

  • Industrial Automation: Monitor sensor inputs and control actuators, machines, or alarms based on configurable logic.
  • Smart Home & Building Automation: Automate lighting, HVAC systems, and appliances using environmental data and remote control.
  • IoT & Cloud-Based Monitoring: Stream real-time data to AWS, Azure, or private MQTT brokers for centralized dashboards and alerting.
  • Remote Control Systems: Operate devices from anywhere using the onboard web server or REST APIs.
  • Smart Agriculture: Monitor field conditions and control irrigation or other systems based on environmental triggers.
  • Test Fixtures
  • DIY and Hobby

Key Features

  • 8 Relay Outputs: Available in SPST and SPDT variants. Relay contact ratings depend on the installed relay variant.
  • 8 High-Voltage Digital Inputs: Supports input voltages of up to 24 V for monitoring external signals and equipment.
  • Relay Status LEDs: Individual LEDs indicate the status of each relay on SPST relay variants.
  • Standalone Rule-Based Automation: Create local automation rules to automatically control relays based on input conditions and configured events, without requiring a host PC or cloud connection.
  • Smart Relay Control: Provides intelligent relay control based on configured conditions, inputs, and automation rules.
  • Relay Timer: Configure relays to turn ON or OFF automatically for a specified duration or at configured intervals.
  • Fail-Safe Operation: Configure predefined relay states and actions to maintain safe and predictable operation during communication or system failures.
  • Ethernet Connectivity: Provides reliable wired network connectivity for device access and control.
  • 2.4 GHz Wi-Fi: Provides wireless connectivity for remote monitoring and control.
  • Web Interface: Built-in password-protected web interface for device configuration, monitoring, and relay control.
  • REST API: Enables integration with custom software and automation applications over Ethernet and Wi-Fi.
  • Telnet Interface: Provides command-line access for relay control and device configuration over Ethernet.
  • MQTT/MQTTS Support: Enables integration with MQTT-compatible IoT and cloud platforms for remote monitoring and control over Wi-Fi.
  • Cloud Integration: Supports cloud platforms and services that use MQTT/MQTTS, including AWS, Microsoft Azure, and other MQTT-compatible platforms.
  • DIN Rail Mounting: Supports standard DIN rail installation for convenient deployment in control panels and industrial environments.
  • USB Connectivity: Provides local access and configuration without requiring a network connection.
  • RGB Status Indicator: Provides a quick visual indication of the device’s operating status.

Technical Specifications

Parameter*Value Unit
VariantNLEWR008ANLEWR008A-24NLEWR008BNLEWR008B-24
Basic Specifications
Number of relays8888
Number of Digital Inputs8888
Digital circuit power supply voltage (External)12241224V
Maximum current drawn by digital circuitry 300300300300mA
Digital Inputs Specifications
Minimum DI sink current2.052.052.052.05mA
Maximum DI sink current30303030mA
Recommended sink current 10101010mA
Maximum Low Voltage (VIL)10.210.210.210.2V
Minimum High Voltage (VIH)10.5 10.5 10.5 10.5 V
Maximum High Voltage 24242424V
Relay Specifications
Nominal relay coil voltage12241224V
Nominal coil power consumption (per relay)450450450450mW
Relay contact material Silver Alloy, silver metal-oxideSilver Alloy, silver metal-oxidesilver metal-oxidesilver metal-oxide
Contact rating7A 250VAC
7A 28VDC
7A 250VAC
7A 28VDC
7A/ 277V AC
7A/ 28V DC
7A/ 277V AC
7A/ 28V DC
Maximum switching voltage 250VAC/30VDC250VAC/30VDC277VAC/28VDC277VAC/28VDC
Maximum switching current 7777A
Maximum switching power2500VA/300W2500VA/300W2770VA/ 196W2770VA/ 196W
Contact resistance100100100100mΩ (at 1A 6VDC)
Insulation resistance10001000MΩ
Life expectancy (Electrical)100000100000100000100000Operations (at 7A 250VAC resistive load, room temp)
Life expectancy (Mechanical)10000000100000001000000010000000Operations
Maximum switching on response time 1111second
Maximum switching off response time 9999second
shock resistance (Functional)2942949898m/s2
Shock resistance (Destructive)980980980980m/s2
Vibration resistance10Hz to 55Hz, 1.5mm DA10Hz to 55Hz, 1.5mm DA10Hz to 55Hz, 1.5mm DA10Hz to 55Hz, 1.5mm DA
Relay IndicationAvailableAvailableNot AvailableNot Available

* All parameters considered nominal. Numato Systems Pvt Ltd reserve the right to modify products without notice.
* SPST Variant Datasheet – HF32FV-G Relay
* SPDT Variant Datasheet – HF3FF Relay

Note: Relay ratings are based on the relay manufacturer’s specifications. Actual allowable load depends on load type, switching frequency, ambient conditions, wiring, and the complete module design. Refer to the relay datasheet and application guidelines before switching loads near the maximum rating.

How to use the module

The following section describes how to use this module.

Components/Tools required

Along with the module, you may need the items in the list below for easy and fast installation.

  1. CAT 5e Ethernet Cable(Straight through cable)
  2. 12V/24V 1A DC power supply, depending on the relay variant
  3. USB Type C Cable
  4. Medium-sized Philips screwdriver

Connection Details

connection details

DC Power Supply

DC Power SupplyThis board can be operated using a single DC power supply. Depending on the relay variant, connect either a 12V/24V DC, 1A power supply to the DC jack on the board. The power supply provides power to both the logic circuitry and the relays.

Connecting the power supply incorrectly can cause damage to the module and/or other devices.

USB Interface

The LEO WR 8 Channel Web Relay Module is designed for quick and intuitive operation. With its human-readable command set and standard USB CDC interface, the device can be used with widely available serial terminal applications, with no specialised software required.

It is compatible with most common terminal tools, including:

  • Windows
    • Tera Term
    • PuTTY
  • Linux
    • GNU Screen
    • PuTTY
  • MAC OS X
    • Screen Command
    • CoolTerm

Note: The device is not limited to the above tools and can be used with any standard serial terminal software.

Getting started with the device involves just a few simple steps:

  1. Connect the Device: Plug the module into a USB port on your host system.
  2. Install Drivers (Windows Only): The driver is available on the product page.
  3. Open the COM Port: Open the COM Port assigned to the device using your preferred serial terminal software.
  4. Configure the Device: Configure the device with simple human-readable commands, similar to using DOS or a Bash terminal.
  5. Automate via scripts: Integrate with your application or scripts using a language of choice such as C, Python, Node.js, Perl, or others.
  6. Enable Standalone Automation: Configure Smart Actions and Relay Timers to allow the device to operate independently without a host system.

Use a USB-A to USB-C/ USB-C to USB-C cable to connect to a PC. Please visit accessories to buy cables and accessories for this product.

Ethernet Connectivity

Ethernet port supports

The LEO WR8 features a 10/100 Mbps Ethernet interface, providing network communication speeds of up to 100 Mbps for communication and control of the module.

The module can be connected directly to a computer or to a Local Area Network (LAN) using a standard Ethernet cable.

Example: Connect the LEO WR8 to a network switch using an Ethernet cable to access and control the module from computers or other devices on the same network.

Note: Actual data throughput may vary depending on the network configuration, communication protocol, packet size, and other network conditions.

Wi-Fi Connectivity

The LEO WR8 features built-in 2.4 GHz Wi-Fi for wireless network connectivity, allowing the module to be accessed and controlled without a wired Ethernet connection.

The module supports Wi-Fi Station (STA) mode, allowing it to connect to an existing wireless network. Wi-Fi network settings can be configured through the module’s web interface or USB connection, without requiring additional hardware.

Once connected to the network, the LEO WR8 can be accessed through its web interface and REST API for configuration, monitoring, and control. The module also supports MQTT/MQTTS, allowing relay and device data to be exchanged with MQTT-compatible applications and cloud platforms for remote monitoring and control.

Wi-Fi connectivity makes the LEO WR8 suitable for wireless automation, remote equipment control, IoT applications, and cloud-connected systems.

Relay Contacts

The LEO WR8 is available in SPDT and SPST relay variants. The relay contacts are accessible through the onboard screw terminals for easy connection to external loads.

SPDT Variant – [WR8B, WR8B-24]

The WR8B and WR8B-24 models are equipped with 8 SPDT relays. Depending on the relay variant, the relays are available in 12 V or 24 V coil versions and support switching currents of up to 7 A, subject to the applicable relay specifications.

Each SPDT relay provides three contacts:

  • COM (Common): Common relay contact
  • NO (Normally Open): Connected to COM when the relay is ON
  • NC (Normally Closed): Connected to COM when the relay is OFF

When the relay is OFF, COM is connected to NC. When the relay is ON, COM is connected to NO.

The table below shows the relay contact states:

Relay StateConnection between NC and C Connection between NO and C
OFFCloseOpen
ON Open
Close

SPST Variant – [WR8A, WR8A-24]

The WR8A and WR8A-24 models are equipped with 8 SPST relays. Depending on the relay variant, the relays are available in 12 V or 24 V coil versions and support switching currents of up to 7 A, subject to the applicable relay specifications.

Each SPST relay provides two contacts:

  • IN: Input contact
  • OUT: Output contact

When the relay is ON, the IN and OUT contacts are connected. When the relay is OFF, the connection between IN and OUT is open.

The table below shows the relay contact states:

Relay StateIN to OUT ConnectionLoad Condition
OFFOpenLoad Disconnected
ON ClosedLoad Energized

Digital Input Contacts

In addition to the onboard relays, the LEO WR 8 Channel Web Relay Module features 8 high-voltage digital input channels, designed for reliable interfacing with external signals in industrial environments.

Input Voltage Range

  • Recommended Operating Voltage: Up to 24V
  • Logic LOW (Max): <= 10.2V
  • Logic HIGH (Min): >= 10.5V

Input Current Characteristics

  • Minimum Sink Current: 2.05 mA
  • Maximum Sink Current: 30 mA

Each input channel detects the presence of an external voltage signal and interprets it as a digital HIGH or LOW based on the defined thresholds. These inputs can be used to monitor signals from switches, sensors or any other control systems.

 

Important Notes

  • Ensure input voltages remain within the specified limits to prevent damage.
  • Always use proper grounding and wiring practices in industrial environments.

LED Indication

The LEO WR 8 Channel Web Relay module provides visual feedback through the onboard LED indicator:

  • On Power-On
  • Device Reset
  • Factory Reset
  • Network Status
LED IndicationStatus
Solid RedUSB configuration mode
Blinks in Blue ColourTrying to connect to network
Solid PurpleConnected to Ethernet network
Solid Turquoise BlueConnected to Wi-Fi network
Solid BlueConnected to both Ethernet and Wi-Fi
Blinks in Red ColourFactory reset in progress

Multipurpose Switch

The LEO WR 8 channel Web Relay Module is equipped with a versatile multipurpose switch that enables a range of device management functions:

ActionLED IndicationFunction
Single ClickThe Red LED briefly turns OFF and ON, indicating that the device is restarting.Device Reset: Resets the device and reinitializes.
Press for 7-10 secondsThe Red LED blinks continuously while the factory reset process is in progress.Factory Reset: Device erases all the settings and restores to factory defaults.

Important: Factory reset restores the device to its factory-default configuration and erases all user-configured settings, including network, MQTT, Smart Action, Timer, Fail-Safe, Device ID, username, and password settings. Use the Factory reset feature only to recover the Username/Password/Hostname or when you need to restore the device to its factory-default state.

Factory Reset

The LEO WR 8 Channel Web Relay Module provides a factory reset feature to restore all settings to their original default values.

How to Perform a Factory Reset

You can initiate a factory reset using either of the following methods:

  • Using the Multipurpose Switch: Press and hold the RESET switch for 7 – 10 seconds.
  • Using Command Interface: Execute the factory reset command via the USB console.

Important Notes

  • This operation will reset all user-configured settings, including:
    • Username and Password
    • Device ID
    • Smart Actions and Timer configurations
    • All other user-configured parameters.
  • After reset, the device will revert to factory default credentials, as listed in the table below.

Factory Default Settings

The default configuration after a factory reset is provided in the table below.

User nameadmin
Passwordadmin1234
Host Name - both net0 and net1*Factory set default unique Hostname.
Device ID00000000
net0 IP Address169.254.1.1
Telnet AuthenticationON
Telnet Port23
net1 IP Address169.254.1.1
Access IP - both net0 and net1Disabled
IP0 to IP9255.255.255.255
DHCP Status - both net0 and net1 Enabled
Smart Action Disabled
Relay Power-OnDisabled
GPI Notify FeatureDisabled
IO Fail-Safe Idle

Powering up LEO WR8 after Factory Reset

For a factory-reset device, the recommended configuration sequence is:

Power ON – Connect USB – Log in – Configure Network – Connect to Ethernet/Wi-Fi – Access Web Interface – Configure Application Features

After the network configuration is complete, USB is not required for normal operation. The module can be accessed and controlled through the available network interfaces.

Note: The exact configuration options available through USB, the Web Interface, and network interfaces may vary depending on the firmware version.

Smart Action Engine

The Smart Action Engine enables real-time, rule-based automation by directly mapping digital inputs to relay outputs. It allows the module to respond instantly to input conditions using configurable logic modes such as LOW, HIGH, or FOLLOW.

This feature transforms the device from a simple USB relay interface into an intelligent control system, capable of operating independently without continuous host intervention.

Ready to make your device smarter? Explore the Smart Action Engine command set to discover powerful automation options and enable Smart Action on your device.

Relay Timer Engine

The Relay Timer Engine provides precise time-based control of relay operations. It supports configurable modes such as Delayed ON, Delayed OFF, and Toggle, enabling automation of sequencing, scheduling, and timed switching tasks.

With persistent configuration, the timer functionality continues to operate even after power cycles, making it ideal for autonomous and repeatable control applications.

Discover the possibilities with Relay Timer Engine! Explore the Relay Timer Engine command set to learn how to unlock powerful automation and enable Smart Action on your device.

IO Failsafe Control

The IO Failsafe Control feature ensures safe and predictable system behaviour by monitoring a designated digital input. When the configured input reaches the specified trigger condition, the module automatically drives the relays to a predefined state.

This is essential for implementing safety mechanisms such as emergency shutdowns, fault handling, and enforcing defined system states based on input-triggered conditions.

Take your device automation to the next level! Refer to the IO Failsafe Control command set to explore what’s possible and get started with IO Failsafe.

Supported Error Codes

The LEO WR 8 Channel WEB Relay Module returns error codes to indicate invalid commands or incorrect parameter usage.

These codes help in quickly identifying and resolving issues during operation.

Error CodeError NameDescription
-3Invalid CommandThe device does not recognise the entered command
-2Invalid Argument One or more parameters are incorrect
-51Invalid Relay Timer Limit Timer delay is outside the allowed range
-41Invalid Smart Engine ModeThe IO is already set to a different smart engine mode
-42Invalid Relay ValueThe relay value is outside the allowed range in the smart action engine

Notes:

  • Error codes are returned immediately upon command validation failure
  • Ensure all commands and parameters follow the defined format and limits
  • Refer to individual command sections for valid parameter ranges

Powering Up LEO WR 8 Channel Web Relay Module

Connect a DC power supply and power up the device as mentioned in the DC Power Supply section above. An RGB LED will glow Red for 2 seconds, which indicates active power. Connect the module to a Switch/Router as mentioned in the Ethernet Interface section above. Run the Numato Lab Device Discoverer application (Numato Lab Device Discoverer.jar), and click on Discover Devices. The window will display the IP address, Host Name, MAC Address, and Other information.

IP Address and MAC Address can also be seen in the command prompt, only after connecting the module through the web page. Open the command prompt and type the command ‘arp -a‘. This will display the available network interfaces and connected devices along with the MAC address and IP address of each device. Look for the IP address that corresponds to your device’s MAC address. The 2 MAC addresses and Hostnames for each Relay Module are printed on a label on the board for your convenience. Use the Hostname or the IP address obtained to access the device.

Device USB Mode

Configure LEO WR8 : 8 Channel Web Relay Module

Before configuring the LEO WR8, connect a suitable DC power supply and power on the module. The PWR LED will illuminate to indicate that the device is powered.

The LEO WR8 provides a USB interface for local configuration and device access. It can also be configured and operated over the network using Ethernet or 2.4 GHz Wi-Fi.

 

USB Configuration

USB configuration is useful for initial setup, network configuration, and local device access, especially when the module has not yet been connected to a network.

  1. Connect the LEO WR8 to a PC using a USB-A to USB-C or USB-C to USB-C cable.
  2. Open a serial terminal application such as Tera Term, PuTTY, or another terminal emulator.
  3. Select the COM port assigned to the LEO WR8.
  4. Configure the terminal using the communication settings specified in the USB Interface section.
  5. Connect to the module.

The module will display a login prompt. Enter the appropriate credentials to access the configuration interface.

For a device with factory-default settings, use:

  • Username: admin
  • Password: admin1234

After successful authentication, a login success message will be displayed, and the available USB configuration commands can be accessed.

Security Recommendation: Change the default password immediately after the first login. Do not expose the device to an untrusted network while default credentials are still enabled.

Explore the USB Configuration command set to get hands-on experience with configuring your device.

Network Configuration

Once the network settings are configured, the LEO WR8 can be connected to an existing network through Ethernet or 2.4 GHz Wi-Fi.

Depending on the network interface, the following communication methods are available:

Interface Available Communication
Ethernet Web Interface, REST API, Telnet
Wi-Fi Web Interface, REST API, MQTT/MQTTS

The Web Interface provides a convenient way to configure and monitor the device through a standard web browser.

The REST API allows the LEO WR8 to be integrated with custom applications and automation software.

The Telnet interface provides command-line access to the device over Ethernet.

The MQTT/MQTTS interface allows the LEO WR8 to communicate with MQTT-compatible applications and cloud platforms for remote monitoring and control over Wi-Fi.

Discover more about your device configuration by exploring the Ethernet Configuration command set or/and Wi-Fi Configuration command set.

Device Application Mode

Accessing the module

The module can be monitored and controlled by using the interfaces below.

  1. Through HTML/Web Page served from the device – Ethernet interface.
  2. Through HTML/Web Page served from the Wi-Fi interface.
  3. Through a Serial terminal Emulator that supports TELNET (Eg: Hyper Terminal, TeraTerm, PUTTY…).
  4. Through REST API commands.

Accessing the module using Ethernet web interface

The easiest method for controlling the module is through web page served from the device. To open the administration web page, type in the IP address or hostname.local into the address bar of any web browser and press enter.

 

You will be prompted to enter your Username and Password. The default username is ‘admin,’ and the default password is “admin1234“. Once logged in, you may change the Username and Password.

Enter the default User name and Password, then click Sign In.

 

You will be presented with the device home page that shows the status of Relays and GPIs.

Get started with application through Ethernet Web Interface .

Accessing the module using Wi-Fi web interface

The easiest method for controlling the module is through a web page served from the device. To open the administration web page, type the IP address or hostname.local into the address bar of any web browser and press Enter.

You will be prompted to enter your username and Password. The default username is ‘admin,’ and the default password is “admin1234“. Once logged in, you may change the Username and Password.

Enter the default username and password, then click Sign In.

You will be presented with the device home page that shows the status of Relays and GPIs.

Get started with application through Wi-Fi Web Interface .

Controlling the module through Telnet interface

The simple, human-readable ASCII command set makes it easy to control the relays through the Telnet interface. The following sections give examples of how to use the module with PuTTY and TeraTerm.

To use this module with PuTTY, please follow the steps below.

  • Connect the module to the LAN.
  • Open PuTTY and enter the IP address corresponding to the module, leaving the port number as 23.
  • Click Open.
  • If everything goes well, you should be presented with a screen as below.
  • Type in the TELNET User name and Password when asked and press enter key.
  • Commands listed in the table in  section “Sending Commands” can be entered here now. For example, here is the response for “ver” command.
  • Using the relay module with TeraTerm is just as easy. Please follow the steps below.

TeraTerm is an open source software. A free copy can be downloaded from http://en.sourceforge.jp/projects/ttssh2/releases/.

  • Run TeraTerm and type in the IP address corresponding to the module in the “New connection” dialog and click OK.
  • Then select the terminal setup from the setup button and make sure the settings are as shown below, and press OK.
  • Type the User name and Password when asked.
  • Press ENTER key and the command prompt should appear. Commands listed in the table in section “Sending Commands” can be entered here now. For example, here is the response for “ver” command.

Get started with application commands by referring to the Sending commands.

Controlling through REST API commands

This module supports REST API commands.

Refer to the ‘REST API Command Set‘ knowledge base to know more.

Below is the example image related to controlling these modules through REST API commands.

Configuration Command Set

Device configuration

No. Command ParametersExample Description
Device Configuration
1vernoneverReturns firmware Version
2infononeinfoDisplay information about the module including Failsafe and Power-on status
3idget/set xxxxxxxxid get, id set 12345678Reads/Sets id of the module
4usrget/set xxxxxxxx usr get, usr set admin Reads/Sets User name
5pass
get/set xxxxxxxx pass get, pass set admin1234 Reads/Sets Password
6usr authget/on/offusr auth get, usr auth on, usr auth offReturns User Auth status, Enable/Disable Authentication
7accessip get/on/off/set N xxx.xxx.xxx.xxxaccess ip getRead the stored IP in the memory.
access ip on/offEnable or disabling the IP based access to the module, this command adds filtering. Once the command is enabled, the stored IP using the access ip set command will be able to access the module. By default access IP is disabled.
access ip set N xxx.xxx.xxx.xxxSet the acceptable IP in the network and save the same. Where N is the number 0-9, maximum 10 IP we can store in the non-volatile memory.
Eg: access ip set 0 192.168.0. 2
8rebootnonerebootReboot does a soft-reset.
9app modenoneapp modeExit the configuration interface and enter to the application mode and start the application communications.
10fact resetnonefact resetPerform device factory reset

Network0 (Ethernet) Configuration

No. Command ParametersExample Description
Network0 Configuration
1net0 mac getnet0 mac getRead the MAC id of the NET0 Ethernet Interface.
2hostname getnet0 hostname getShows the hostname of the Ethernet interface
3hostname set xxxxxxxxxxxxxxxnet0 hostname set numato-ethSets the hostname to the Ethernet Interface.

Hostname length must be between 1 and 15 characters, and only the '-' symbol is allowed
4dhcp getnet0 dhcp getShows the DHCP status of the Ethernet Interface
5dhcp on/offnet0 dhcp on/offEnable or disable the DHCP of the Ethernet Interface
6ip getnet0 ip getRead the status of DHCP and the static IP of the Ethernet Interface. If DHCP is enabled it will display the DHCP status, and if it is disabled it will display the static IP too
7ip set xxx.xxx.xxx.xxxnet0 ip set 192.168.5.36Sets the static IP to the Ethernet Interface.
8sm getnet0 sm getRead the Subnet Mask of the Ethernet Interface. If DHCP is enabled it will display the DHCP status and if it is disabled it will display the Subnet Mask value.
9sm set xxx.xxx.xxx.xxxnet0 sm set 255.255.255.0Sets the Subnet Mask to the Ethernet Interface.
10gw getnet0 gw getReads the Gateway of the Ethernet Interface. If DHCP is enabled it will display the DHCP status and if it is disabled it will display the Gateway value.
11gw set xxx.xxx.xxx.xxxnet0 gw set 192.168.5.1Sets the gateway to the Ethernet Interface.
Telnet Configuration
12telnet auth getnet0 telnet auth getRead the status of telnet authentication.
13telnet auth on/offnet0 telnet auth on/offEnable and disable the telnet authentication. telnet auth on enabling the telnet authentication and telnet off disabling the telnet authentication.
14telnet port getnet0 telnet port getShows the telnet port.
15telnet port set xxxxxnet0 telnet port set xxxxxSets the telnet port, where xxxxx can be in the range of 1 to 65535. The default value of the telnet port is 23.

Network1 (Wi-Fi) Configuration

No. Command ParametersExample Description
Network1 Configuration
1net1mac getnet1 mac getRead the MAC id of the NET1 Wi-Fi Interface.
2hostname getnet1 hostname getShows the hostname of the Wi-Fi interface
3hostname set xxxxxxxxxxxxxxxnet1 hostname set Numato123Set a unique hostname for the device. This is useful for identifying the device on the network and can be customized to reflect the device’s role or location.
Hostname length must be between 1 and 15 characters, and only the '-' symbol is allowed
4ssid getnet1 ssid getShows the SSID of the configured Wi-Fi network
5ssid set xxxxxxxxnet1 ssid set adminEnter the SSID (network name) of the Wi-Fi network that the device should connect to. This is the name of the wireless network that the device will search for and connect to.

SSID length must be between 1 and 31 characters and '\', '/', space symbols are restricted
6pass getnet1 pass getShows the password of the configured Wi-Fi network
7pass set xxxxxxxxnet1 pass set admin1234Enter the Wi-Fi password for the SSID you've selected. This ensures secure communication between the device and your network.

Password length must be between 1 and 31 characters and '\', '/', space symbols are restricted
8dhcp getnet1 dhcp getShows the DHCP status of the Wi-Fi Interface
9dhcp on/offnet1 dhcp on/offEnable or disable the DHCP of the Wi-Fi Interface
10ip getnet1 ip getRead the status of DHCP and the static IP of the Wi-Fi Interface. If DHCP is enabled it will display the DHCP status and if it is disabled it will display the static IP too
11ip set xxx.xxx.xxx.xxxnet1 ip set 192.168.5.48Sets the static IP to the Wi-Fi Interface.
12sm get net1 sm getRead the Subnet Mask of the Wi-Fi Interface. If DHCP is enabled it will display the DHCP status and if it is disabled it will display the Subnet Mask value.
13sm set xxx.xxx.xxx.xxxnet1 sm set 255.255.255.0Sets the Subnet Mask to the Wi-Fi Interface.
14gw getnet1 gw getReads the Gateway of the Wi-Fi Interface. If DHCP is enabled it will display the DHCP status and if it is disabled it will display the Gateway value.
15gw set xxx.xxx.xxx.xxxnet1 gw set 192.168.5.1Sets the gateway to the Wi-Fi Interface.
16pdns getnet1 pdns getReads the Primary DNS of the Wi-Fi Interface. If DHCP is enabled it will display the DHCP status and if it is disabled it will display the Primary DNS value.
17pdns set xxx.xxx.xxx.xxxnet1 pdns set 8.8.8.8Sets the primary dns to the Wi-Fi Interface.

Sending Commands

One of the most powerful features of this module is the simple easy to use command set it supports. This command set allows for a very simple interface to access the features of the module through TELNET protocol. The following sections give details of the command set and how to use the command set.

The command set

This product supports a very simple command set that is designed to be less cryptic and easy to use manually (using terminal emulation programs that support TELNET) or through a program written in one of the many supported languages

List of currently supported commands.

No.Command
ParametersExample Description
1verNoneverReturns firmware Version
2idget/set xxxxxxxxid get, id set 12345678Reads/Sets id of the module
3usr get/set xxxxxxxx usr get, usr set admin Reads/Sets User name
4pass get/set xxxxxxxxx pass get, pass set admin1234Reads/Sets Password
5usr authget/on/offusr auth get, usr auth on, usr auth offReturns User Auth status, Enable/Disable Authentication
6relayon/off/status [relay number]/status/on all/off all/
write [relay_group] [relay_map]/
pwron [relay_group] [relay_map]/get/disable/
tmr get [relay_number]/ get/disable/disable [relay_number]/[relay_number] [mode] [delay_seconds]
relay on 000,
relay off 000,
relay status 000,
relay status,
relay on all,
relay off all,
relay write A 00ff,
relay pwron A 00ff,
relay pwron get,
relay pwron disable,
relay tmr get 000,
relay tmr get,
relay tmr disable,
relay tmr disable 000,
relay tmr 000 M0 2
Relay Control
7gpigpi read [input number], gpi notify on/off/getgpi read 000,
gpi read,
gpi notify on,
gpi notify off.
gpi notify get
Monitor General Purpose Input
8smartget/-i/-r/disable/
[input] [mode] [target_output] [value]
smart get 000, smart -i 000, smart -r 000, smart disable, smart 000 L 000 1Read configured data, clear configured input, clear configured relay, disable entire smart action feature, configure smart feature
9fsget input_number/reset/disable/
[input] [mode] [relay_group] [relay_map]
fs get 000, fs reset, fs disable, fs 000 L A 0012Read status of IO failsafe, Manual Reset Failsafe, Disable Failsafe, Configure Failsafe
10infononeinfoDisplay information about the module including Smart Action and Power-on status
11rebootnonerebootPower reset does a soft-reset.
12config modenoneconfig modeExit the application mode and enter to the configuration interface and start the configuration via USB.
13factresetfact resetPerform device factory reset Configure the module to factory default.

The tables below provide more detailed information about available commands.

Device Command Set

No. Command Example Description
1ver ver This command returns the current firmware version of the device.
Command Format
ver

Response Format
xxxx
xxxx – Firmware version string

Description
Returns the firmware version currently running on the device.

Example
ver Returns firmware version

Notes
The version format may vary depending on the firmware release.
2idid get
id set xxxxxxxx
This command is used to read and configure the device ID.
Command Format
id get
id set x
x – New device ID (exactly 8 characters)

Description
id get returns the current device ID.
id set x updates the device ID to the specified value.

Example
id get Returns the current device ID
id set DEV12345 Sets the device ID to "DEV12345"

Notes
The device ID must be exactly 8 characters in length.
Changing the device ID may affect identification in connected systems or applications.n a new ID to the module. “x” stands for alphanumeric characters including symbols. The new ID must be exactly 8 characters in length.
3usr
usr get
usr set xxxxxxxx
This command is used to read and configure the device username.
Command Format
usr get
usr set x
x – New username (1 to 8 characters)

Description
usr get returns the current username configured on the device.
usr set x updates the username to the specified value.

Example
usr get Returns the current username
usr set admin Sets the username to "admin"

Notes
Username length must be between 1 and 8 characters.
Changing the username affects authentication over the USB interface.
4passpass get
pass set xxxxxxxxx
This command is used to read and configure the device password.
Command Format
pass get
pass set x
x – New password (9 to 31 characters, alphanumeric and symbols supported are !, @, ^, (, ))

Description
pass get returns the current password configured on the device.
pass set x updates the device password to the specified value.

Example
pass get Returns the current password
pass set admin1234 Sets the password to "admin1234"

Notes
Password length must be between 9 and 31 characters.
Use a strong password to ensure secure access to the device.
Changing the password affects authentication over the USB interface.
5usr authusr auth get

This command returns the current USB authentication status.
Command Format
usr auth get

Response Format
USR Authentication Disabled – Authentication is DISABLED
USR Authentication Enabled– Authentication is ENABLED

Description
Returns whether USB authentication is currently enabled or disabled.

Example
usr auth get Returns USR Authentication Enabled if authentication is enabled, otherwise USR Authentication Disabled

Notes
Ensure authentication is enabled for secure operation.
When disabled, commands can be executed without credentials.
usr auth onThis command enables USB authentication for the device.
Command Format
usr auth on

Description
Enables authentication over the USB interface.
Once enabled, valid credentials are required to execute commands.

Example
usr auth on Enables USB authentication

Notes
Ensure valid username and password are configured before enabling authentication.
If credentials are unknown, use factory reset to restore default access.
usr auth offThis command disables USB authentication for the device.
Command Format
usr auth off

Description
Disables authentication over the USB interface.
Once disabled, commands can be executed without requiring a username or password.

Example
usr auth off Disables USB authentication

Notes
Disabling authentication reduces access security.
It is recommended to use this feature only in trusted environments.
6infoinfoThis command displays module information, including Smart Action status, Power-on configuration, and IO Failsafe status.
Command Format
info

Description
Returns a summary of key module configurations in a single response.
Helps in quickly verifying system setup and operational status.

Example
info Returns module configuration summary

Notes
The response format may vary based on firmware version.
Use individual commands for detailed configuration of each feature.
7config modeconfig modeThis command exits the application interface and enter to the configuration mode.

Command Format
config mode

Description
The device restarts the configuration mode without altering any stored configuration.

Example
config mode Enters configuration mode
8rebootrebootThis command performs a soft reset of the device.
Command Format
reboot

Description
Restarts the device without altering any stored configuration.
All settings, including Smart Action, Timer, Failsafe, and credentials, remain unchanged.

Example
reboot Performs a device soft reset

Notes
The device will briefly disconnect and restart after execution.
Use this command to recover from temporary issues or apply configuration changes.
9fact resetfact resetThis command performs a factory reset of the device.
Command Format
fact reset

Description
Restores the device to factory default settings.
All configurations, including Smart Action, Timer, Failsafe, credentials, and other user-defined parameters, will be erased.

Example
fact reset Performs a device factory reset

Notes
The device will briefly disconnect, the LED will blink during the reset process, and the device will restart upon completion.
Use this command to recover the device or reset all configurations.
This action cannot be undone.

Relay Command Set

No. Command Example Description
1relayrelay on xxxThis command turns ON a specific relay channel.
Command Format
relay on xxx
xxx – Relay number (Range: 000 to 007, numbering starts from 0)

Description
Turns ON the selected relay channel.

Example
relay on 000 Turns ON Relay 0

Notes
Ensure the relay number is within the valid range (000–007).
The command immediately updates the relay state.
If a relay is mapped to smart action or relay timer, manual control will be restricted
2relay off xxxThis command turns OFF a specific relay channel.
Command Format
relay off xxx
xxx – Relay number (Range: 000 to 007, numbering starts from 0)

Description
Turns OFF the selected relay channel.

Example
relay off 000 Turns OFF Relay 0

Notes
Ensure the relay number is within the valid range (000–007).
The command immediately updates the relay state.
If a relay is mapped to smart action or relay timer, manual control will be restricted
3relay status xxxThis command returns the current status of a specific relay channel.
Command Format
relay status xxx
xxx – Relay number (Range: 000 to 007, numbering starts from 0)

Response Format
on or off

on – Relay is ON
off – Relay is OFF

Description
Returns the current state of the selected relay channel.

Example
relay status 000 Returns status of Relay 0

Notes
Ensure the relay number is within the valid range (000–007).
The response reflects the real-time state of the relay at the moment of execution.
4relay statusThis command reads the current status of all relays in a single operation.
Command Format
relay status

Response Format
A:XXXX
XXXX – Current relay state (hexadecimal value)

Description
The returned value represents the state of all relays in the selected group.
Each bit corresponds to one relay channel.
0 – Relay OFF
1 – Relay ON

Example
A:0000 – All relays are OFF
A:00FF – All relays are ON

Group Representation
A – Group A (first 16 relays. )
Each bit represents one relay channel.

Value Range
WR8: 0000 to 00FF (8-bit)
WR16: 0000 to FFFF (16-bit)
5relay on allThis command turns ON all relay channels.
Command Format
relay on all

Description
Turns ON all relays in a single operation, regardless of their current state.

Example
relay on all Turns ON all relays

Notes
This command immediately sets all relay outputs to ON.
It overrides any previously set relay states.
If a relay is mapped to smart action or relay timer, manual control will be restricted
6relay off allThis command turns OFF all relay channels.
Command Format
relay off all

Description
Turns OFF all relays in a single operation, regardless of their current state.

Example
relay off all Turns OFF all relays

Notes
This command immediately sets all relay outputs to OFF.
It overrides any previously set relay states.
If a relay is mapped to smart action or relay timer, manual control will be restricted
7relay write A 00xxThis command controls all relays in a single operation using a hexadecimal value.
Command Format
relay write G xxxx
G – Relay group identifier
A – Group A (relays 0 to 15)
xxxx – Relay state value (hexadecimal)

Description
Sets the state of multiple relays simultaneously.
Each bit in the hexadecimal value represents one relay in the group.

Bit Representation
0 – Relay OFF
1 – Relay ON

Example
relay write A 00FF – Turns ON all relays in Group A

Value Range
WR8: 0000 to 00FF (8-bit)
WR16: 0000 to FFFF (16-bit)

Notes
Each bit position corresponds to a relay channel within the group.
Ensure correct bit mapping to avoid unintended relay switching.
If a relay is mapped to smart action or relay timer, manual control will be restricted
8relay pwron A 00xxThis command sets the relay power-on state for the module.
Command Format
relay pwron G xxxx
G – Relay group identifier
A – Group A (first 16 relays)
xxxx – Relay state value (hexadecimal)

Description
Defines the relay states that will be applied when the device powers on or resets.
Each bit in the hexadecimal value represents the state of a relay.

Bit Representation
0 – Relay OFF
1 – Relay ON

Example
relay pwron A 0003
0000 0000 0000 0011 → Relays 0 and 1 ON, all others OFF

Value Range
WR8: 0000 to 00FF (8-bit)
WR16: 0000 to FFFF (16-bit)

Notes
The configured state is applied on device power-up or reset.
Ensure correct bit mapping to avoid unintended relay activation.
If a relay is mapped to smart action or relay timer, manual control will be restricted
relay pwron getThis command reads the power-on status of all relays in a single operation.
Command Format
relay pwron get

Response Format
A:XXXX
XXXX – Power-On values of the relays (hexadecimal value)

Description
The returned value represents the state of all relays in the selected group.
Each bit corresponds to one relay channel.
0 – Relay OFF
1 – Relay ON

Example
A:0000 – All relays are OFF
A:00FF – All relays are ON

Group Representation
A – Group A (first 16 relays)
Each bit represents one relay channel

Value Range
WR8: 0000 to 00FF (8-bit)
WR16: 0000 to FFFF (16-bit)
relay pwron disableThis command disables the Relay Power-On feature for all relay channels.
Command Format
relay pwron disable

Description
Disables power-on feature to all relays.
Once disabled, no relay will operate based on power-on settings.

Example
relay pwron disable Disables power-on feature to all relays

Notes
Use the power-on command to re-enable power-on based behavior.
Relay Timer Commands
9relay tmr get xxxThis command returns the current configuration and status of a specific relay timer.
Command Format
relay tmr get xxx
xxx – Relay number (Range: 000 to 007, numbering starts from 0)

Response Format
Mx D:yyyy

M:Mx – Timer mode (M0 [Delayed ON], M1 [Delayed OFF], M2 [Toggle])
D:yyyy – Delay value in seconds

Description
Returns the timer configuration for the selected relay.
Includes the configured timer mode and delay value.

Example
relay tmr get 000 Returns timer status for Relay 0

Notes
Ensure the relay number is within the valid range (000–007).

If no timer is configured and the M0 or M1 delay expires, the response will indicate “timer not active”
10relay tmr getThis command returns the list of relays with timer configurations.
Command Format
relay tmr get

Response Format
xxx xxx xxx
xxx – Relay numbers with timer configured

Description
Returns a list of relay channels for which timer functionality is currently configured.
Only relays with active timer settings are included in the response.

Example
relay tmr get
000 002 005
Indicates that relay timers are configured on Relay 0, 2, and 5.

Notes
If no relay timers are configured, the response may indicate an empty or default state.
Use relay tmr get xxx for detailed timer configuration of a specific relay.
11relay tmr disable xxxThis command disables the relay timer configuration for the specified relay channel.
Command Format
relay tmr disable xxx
xxx – Relay number (Range: 000 to 007)

Description
Disables the timer configured for the selected relay.
Once disabled, the relay will no longer operate based on timer settings.

Example
relay tmr disable 000 Disables timer for Relay 0

Notes
Ensure the relay number is within the valid range (000–007).
12relay tmr disableThis command disables the Relay Timer feature for all relay channels.
Command Format
relay tmr disable

Description
Disables all configured relay timers.
Once disabled, no relay will operate based on timer settings.

Example
relay tmr disable Disables all relay timer operations

Notes
Use the timer configuration command to re-enable timer-based behavior.
13relay tmr [relay_number] [timer_mode] [timer_delay]This command configures the timer behavior of a specific relay channel, enabling precise control over relay operation based on time.
Command Format
relay tmr xxx mode delay
xxx – Relay number (Range: 000 to 007)

mode – Defines the operating mode of the relay timer
M0 – Delayed ON
M1 – Delayed OFF
M2 – Toggle Timer

delay – Time delay in seconds (Range: 1 to 3600 seconds)

Description
Configures time-based behavior for the selected relay channel.
The relay action depends on the selected mode and delay value.

Examples
relay tmr 000 M0 1 – Turns ON Relay 0 after a delay of 1 second
relay tmr 000 M1 4 – Turns OFF Relay 0 after a delay of 4 seconds
relay tmr 000 M2 10 – Toggles Relay 0 every 10 seconds

Notes
Timer configurations are persistent and remain active even after a power reset.
A configured timer continues to operate until it is explicitly disabled or the device is factory reset.
If a relay is already mapped to smart action, relay timer cannot be configured
If the relay timer mode is set to M0 or M1, the relay becomes available for manual control after the specified delay

GPI Command Set

No.Command
Example Description
1gpigpi read xxxThis command reads the current state of a specific digital input (GPI).
Command Format
gpi read xxx
xxx – Digital input number (Range: 000 to 007)

Response Format
0 or 1
0 – Input is LOW
1 – Input is HIGH

Description
The command returns the instantaneous logic level of the selected digital input.

Example
gpi read 000 Returns 0 or 1 depending on the current state of GPI 0

Notes
Ensure the input number is within the valid range (000–007).
The response reflects the real-time state of the input at the moment of execution.
2gpi readThis command reads the current status of all digital inputs in a single operation and returns the values grouped by input channels.
Command Format
gpi read

Response Format
A:XXXX
XXXX – Current digital input state (hexadecimal value)

Description
The returned value represents the state of all digital inputs in the selected group.
Each bit corresponds to one input channel.
0 – GPI LOW
1 – GPI HIGH

Example
A:00FF – All inputs in Group A are HIGH
A:0001 – GPI 0 is HIGH, all other inputs are LOW

Group Representation
A – Group A (first 16 digital inputs)
Each bit represents one input channel
0 – GPI LOW
1 – GPI HIGH

Value Range
0000 to 00FF (8-bit)
3gpi notify onThis command enables digital input (GPI) change notifications. When enabled, the device monitors input state changes and sends a notification to the host whenever a change is detected.
Command Format
gpi notify on

Notification Format
A:XXXX/YYYY
XXXX – Current input state
YYYY – Previous input state

Description
A notification is sent only when a change is detected in any input bit.
The value represents the state of all inputs in the group using hexadecimal format.

Example
A:00FE/00FF
Previous state: 00FF
Current state: 00FE
This indicates that GPI 0 changed from HIGH (1) to LOW (0), triggering the notification.

Group Representation
A – Group A (first 16 digital inputs)
Each bit represents one input channel
0 – GPI LOW
1 – GPI HIGH

Value Range
0000 to 00FF (8-bit)
4gpi notify offThis command disables the GPI change notification feature.
Command Format
gpi notify off

Response Format
Gpi Notify Disabled

Description
Disables automatic notifications for digital input state changes. Once disabled, the device will no longer send updates to the host when input states change.

Example
gpi notify off Disables GPI change notifications
5gpi notify getThis command returns whether the GPI change notification feature is enabled or disabled.
Command Format
gpi notify get

Response Format
Gpi Notify Enabled or Gpi Notify Disabled

Description
Returns the current status of the gpi change notification feature.

Example
gpi notify get Returns Gpi Notify Enabled or Gpi Notify Disabled

Standalone Commands

Standalone commands are supported in both USB Configuration Mode and Telnet Application Mode, providing flexibility in configuring and managing the device through either interface. These commands include the Smart Action Engine and IO Fail-safe Control commands, which allow users to configure automation actions and manage fail-safe behaviour effectively.

Smart Action Engine Configuration

No. Command ParametersExample Description
1smartget xxx/ get/ -i xxx/ -r xxx/disable/
[input] [mode] [target_output] [value]
smart get 000,
smart -i 000,
smart -r 000,
smart disable,
smart 000 L 000 1
Read configured data,
clear configured input,
clear configured relay,
disable entire smart action feature,
configure smart feature
Smart Action Engine Detailed Commands
1smartget xxxsmart get 000This command returns the current Smart Action configuration for a specific digital input channel.
Command Format
smart get xxx
xxx – Digital input number (Range: 000 to 007)

Response Format
M:L R:000:H
M – Input mode (L: LOW, H: HIGH, F: FOLLOW)
R – Relay number
H / L – Trigger value (HIGH / LOW)

Description
Returns the Smart Action settings configured for the selected digital input
Includes operating mode, mapped relay outputs, and configured trigger values

Example
smart get 000 Returns Smart Action configuration for Digital Input (GPI) 0

Notes
  • Ensure the input number is within the valid range (000–007)
  • If no Smart Action is configured, the response will indicate I:000 not mapped
2getsmart getThis command returns the list of digital inputs that have Smart Action configured.
Command Format
smart get

Response Format
Mapped IOs: xxx xxx xxx

xxx – Digital input numbers with Smart Action configured

Description
Returns a list of digital input channels for which Smart Action is currently configured.
Only mapped inputs are included in the response.

Example
smart get
Mapped IOs: 000 001 007
Indicates that Smart Action is configured on Digital Inputs 0, 1, and 7.

Notes
If no Smart Action is configured, the response may indicate an empty or default state.
Use smart get xxx for detailed configuration of a specific input.
3-i xxxsmart -i 000This command disables the configured digital input for the specified channel.
Command Format
smart -i xxx
xxx – Digital input number (Range: 000 to 007)

Description
Disables the selected digital input channel.

Example
smart -i 000 Disables Smart action mapped on digital Input (GPI) 0

Notes
Ensure the input number is within the valid range (000–007).
4-r xxxsmart -r 000This command disables the configured relay for the specified channel.
Command Format
smart -r xxx
xxx – Relay number (Range: 000 to 007)

Description
Disables the selected relay channel mapped to smart action.

Example
smart -r 000 Disables Relay 0 mapped to smart action

Notes
Ensure the relay number is within the valid range (000–007).
5disablesmart disableThis command disables the Smart Action feature for all input channels.
Command Format
smart disable

Description
Disables all configured Smart Actions.
Once disabled, no digital input will trigger any relay output based on Smart Action logic.

Example
smart disable Disables Smart Action feature for all inputs
6smart [input] [mode] [target_output] [value]smart 000 L 000 1This command configures the Smart Action feature.
Smart Action maps digital inputs to relay outputs and automates relay control based on input state.
Command Format
smart xxx mode target_output value
xxx – Digital input number (Range: 000 to 007)
mode – Defines the trigger condition for the relay
L – Trigger when input is LOW
H – Trigger when input is HIGH
F – Follow mode (relay follows input state)
target_output – Relay to be controlled by the selected digital input (Range: 000 to 007)
value – Relay output state when triggered
0 – Relay OFF
1 – Relay ON
Not required in F (Follow) mode

Description
Each command links a digital input (same index as xxx) to a relay output.
The relay action depends on the selected mode and trigger condition.

Examples
smart 000 L 000 1 – When digital input 0 goes LOW, Relay 0 turns ON
smart 001 H 002 0 – When digital input 1 goes HIGH, Relay 2 turns OFF
smart 003 F 003 – Relay 3 follows digital input 3 (LOW - OFF, HIGH - ON)

Notes
Digital input index corresponds to the input used in the command.
Follow mode (F) continuously mirrors input state without delay.
If a relay is mapped to relay timer, the same relay cannot be configured with smart action feature
One relay can be mapped to only one input, One input can have multiple relays mapped to it

IO Failsafe Control Configuration

No. Command ParametersExample
Description
1fsget/reset/disable/
[input] [mode] [relay_group] [relay_map]
fs get,
fs reset,
fs disable,
fs 000 L A 0012
Read status of IO failsafe,
Manual Reset Failsafe,
Disable Failsafe,
Configure Failsafe
IO Failsafe Control Detailed Commands
1fsgetfs getThis command returns the IO Failsafe configuration for the specified digital input.
Command Format
fs get

Response Format
I:xxx M:X G:X V:xxxx
I:xxx – Digital input number
M:X – Trigger mode (L: LOW, H: HIGH)
G:X – Relay group (e.g., A)
V:xxxx – Relay state value (hexadecimal)

Description
Returns the configured failsafe settings for the selected digital input.
Includes trigger mode, relay group, and relay output value.

Example
fs get Returns failsafe configuration for Digital Input 0

Notes
If no failsafe is configured, the response will indicate "FS Not Configured".
2resetfs resetThis command performs a manual reset of the IO Failsafe condition to resume normal device operation.
Command Format
fs reset

Description
Clears the active failsafe state triggered by a digital input.
Restores normal operation of relay outputs and system behavior.

Example
fs reset Clears the failsafe condition and resumes operation

Notes
Use this command after resolving the condition that triggered the failsafe.
If the trigger condition still exists, the failsafe may be reactivated immediately.
3disablefs disableThis command disables the IO Failsafe feature completely.
Command Format
fs disable

Description
Disables all configured IO Failsafe behavior.
Once disabled, digital inputs will no longer trigger failsafe actions.

Example
fs disable Disables IO Failsafe feature

Notes
Use the configuration command to reactivate failsafe behavior.
4fs [input] [mode] [relay_group] [relay_value]fs 000 L A 0012This command configures the IO Failsafe feature, enabling the module to automatically set relay states based on a defined digital input condition.
Command Format
fs xxx mode G xxxx
xxx – Digital input number
Note: The IO Failsafe feature currently supports Digital Input 0 only
mode – Defines the trigger condition
L – Trigger when input is LOW
H – Trigger when input is HIGH

G – Relay group identifier
A – Group A (first 16 relays)
xxxx – Relay state value (hexadecimal)

Description
Defines the relay output state when the specified digital input reaches the configured condition.
Each bit in the hexadecimal value represents one relay.

Bit Representation
0 – Relay OFF
1 – Relay ON

Example Value
0003 – 0000 0000 0000 0011
Relays 0 and 1 ON, all others OFF

Value Range
WR8: 0000 to 00FF
WR16: 0000 to FFFF

Examples
fs 000 L A 0012
When Digital Input 0 goes LOW, relays are set according to 0012
Relay 1 and Relay 4 turn ON, all others turn OFF

fs 000 H A 0012
When Digital Input 0 goes HIGH, relays are set according to 0012
Relay 1 and Relay 4 turn ON, all others turn OFF

Important Note: Once Fail-safe is triggered, relay control is disabled. Smart Action Engine rules, relay timers, and power-on commands are saved and will resume operation only after the Fail-safe condition is resolved.

Ethernet Web Interface

Through the Ethernet Web Interface, you can monitor and control GPIs and relays, as well as configure device settings and network settings.

GPI, Relay Status and Control

8 Relays on the board can be controlled over Ethernet. The Relay Index shows the corresponding relay on the board. Relays on the board can be turned on/off by clicking the Toggle Relay button next to the corresponding relay index. The status of the relays changes automatically for easy identification.

This board has 8 general-purpose high-voltage inputs. The status of the GPIs is shown on the home page.

Device Settings

Device Settings include Device Info, User Account, and Device Management.

Device Info

The Device Settings page shows the Device ID, firmware version, and serial number, and allows logged-in users to update and save the Device ID.

FieldDescription
Device IDDisplays and allows users to set the Device ID.
Firmware VersionDisplays the current version of the firmware installed on your device.
Device Serial NumberThe serial number specific to your device. This number is used for identification and support purposes.

User Account

In the User Account section, you can manage your web login, including updating your Username and Password. This is important for keeping your account secure and ensuring only authorised users can access the device settings.

FieldDescription
UsernameYou can change your username by entering a new one in the provided field. Make sure to choose a unique and memorable username for easy access.
PasswordEnter your new password here. Please follow the password strength requirements to ensure your password is strong and secure.
Confirm PasswordRe-enter the new password here to confirm that both entries match. If they do not match, an error message will appear to help you correct it.

Important Note: Your password will only be updated if both the New Password and Confirm Password fields match exactly. If they don’t match, a Warning message will display, and you will need to correct it before proceeding.

Important Update Information: Once you update the User Account Password, the web login password will be updated simultaneously. This means that the new password will be used for the web login to your device’s dashboard. Remember this new password for all future logins to your device.

Device Management

In the Device Management section, you can perform essential actions to manage your device, including rebooting the device and restoring it to its factory settings.

ActionDescription
RebootThis option allows you to reset the device. Rebooting the device can be useful for applying new configurations and settings.
Config ModeThis option allows you to switch the device to USB Configuration mode
Factory ResetThis option restores the device to its original factory settings, erasing all user-configured settings and data. After a factory reset, the device will return to its default configuration.

Important Note:  Factory Reset is a permanent action. Once performed, all user-set data will be erased. This action cannot be undone.

Network Settings

The Ethernet Network Settings section allows you to configure the device’s wired network connection.

FieldDescription
MAC AddressDisplays the unique MAC address assigned to the device. This address is used to identify the device on the network.
Host NameSpecifies the hostname of the device. The hostname can be customized to easily identify the device on the network.
Enable DHCPWhen enabled, the device automatically obtains its IP address and other network parameters from a DHCP server.
IP AddressDisplays or specifies the IP address assigned to the device. When DHCP is enabled, this address is assigned automatically.
Subnet MaskSpecifies the subnet mask used to determine the network address range.
Default GatewaySpecifies the gateway address used to communicate with devices outside the local network.

After entering the required network parameters, click Submit to apply the settings.

Important Note: After you have saved all your settings in the device settings or/and network configurations, the changes will only take effect after the device is rebooted. You can reboot the device either:

  • From the Webpage: Use the Reboot option in the device management section to apply all settings.
  • From the Multi-Functionality Switch: Single-click reboots the device with the new configuration set.

After a reboot or a power reset, the module can be accessed via the DNS Hostname or the IP Address.

  • Accessing via DNS Hostname:
    • The device will be accessible via its DNS hostname. By default, the device will be configured with a device-specific unique hostname. The device can be accessed with the postfix “.local”, for example:  hostname.local.
  • Accessing via IP address:
    • If the device was configured with a static IP address, you can access it directly by entering the static IP address into your browser.

    • If the device was set to use dynamic IP (DHCP), you can either check the IP address assigned to the device through your router’s DHCP table or use a “arp -a” on command tool and check the IP assigned to your device MAC.

Wi-Fi Web Interface

Through the Wi-Fi Web Interface, you can monitor and control GPIs and relays, as well as configure Device Settings, Network Settings and MQTT Settings.

GPI, Relay Status and Control

8 Relays on the board can be controlled over Wi-Fi. The Relay Index shows the corresponding relay on the board. Relays on the board can be turned on/off by clicking the Toggle Relay button next to the corresponding relay index. The status of the relays changes automatically for easy identification.

This board has 8 general-purpose high-voltage inputs. The status of the GPIs is shown on the home page.

Device Settings

Device Settings include Device Info, User Account, NET1 OTA Firmware Update and Device Management.

Device Info

The Device Info section provides detailed information about your device. This section is read-only except for the Device ID, which can be edited and saved by logged-in users. You cannot modify the device information here except for the Device ID, but you can refer to it when needed.

FieldDescription
Device IDDisplays Device ID.
Firmware VersionDisplays the current version of the firmware installed on your device.
Device Serial NumberThe serial number specific to your device. This number is used for identification and support purposes.

 

These details are displayed in a simple, easy-to-read format.

User Account

In the User Account section, you can manage your web login, including updating your Username and Password. This is important for keeping your account secure and ensuring only authorized users can access the device settings.

FieldDescription
UsernameYou can change your username by entering a new one in the provided field. Make sure to choose a unique and memorable username for easy access.
PasswordEnter your new password here. Please follow the password strength requirements to ensure your password is strong and secure.
Confirm PasswordRe-enter the new password here to confirm that both entries match. If they do not match, an error message will appear to help you correct it.

Important Note: Your password will only be updated if both the New Password and Confirm Password fields match exactly. If there is a discrepancy, a Warning message will be displayed, and you will need to correct it before proceeding.

Important Update Information: Once you update the User Account Password, the web login password will be updated simultaneously. This means that the new password will be used for the web login to your device’s dashboard. Make sure to remember this new password for all future logins to your device.

NET1 OTA Firmware Update

The Firmware Update section allows you to keep your device up to date with the latest features, improvements, and bug fixes. Firmware updates can be performed only through the NET1 (Wi-Fi) interface.

 

Important: Do not upload any unauthorized images via OTA. Doing so may permanently damage the device.

Device Management

In the Device Management section, you can perform essential actions to manage your device, including rebooting the device and restoring it to its factory settings.

 

 

ActionDescription
RebootThis option allows you to reset the device. Rebooting the device can be useful for applying new configurations and settings.
Config ModeThis option allows you to switch the device to USB Configuration mode
Factory ResetThis option restores the device to its original factory settings, erasing all user-configured settings and data. After a factory reset, the device will return to its default configuration.

Important Note:  Factory Reset is a permanent action. Once performed, all user-set data will be erased. This action cannot be undone.

Network Settings

The Network Settings section allows the device to connect to an existing Wi-Fi network.

FieldDescription
SSIDEnter the name of the Wi-Fi network to which the device should connect.
PasswordEnter the password for the selected Wi-Fi network.
Host NameSpecifies the hostname used to identify the device on the network.
MAC AddressDisplays the MAC address of the Wi-Fi interface.
Enable DHCP ClientWhen enabled, the device automatically obtains its IP address and other network parameters from the network's DHCP server.
IP AddressDisplays or specifies the IP address assigned to the Wi-Fi interface.
Subnet MaskSpecifies the subnet mask for the Wi-Fi network.
Default GatewaySpecifies the gateway address used for communication with other networks or the Internet.
Primary DNSSpecifies the primary DNS server used to resolve domain names into IP addresses.

After entering the required network parameters, click Submit to apply the settings.

After a reboot or a power reset, the module can be accessed via the DNS Hostname or the IP Address.

  • Accessing via DNS Hostname:
    • The device will be accessible via its DNS hostname. By default, the device will be configured with a device specific unique hostname. The device can be accessed with the postfix “.local” example:  hostname.local.
  • Accessing via IP address:
    • If the device was configured with a static IP address, you can access it directly by entering the static IP address into your browser.

    • If the device was set to use dynamic IP (DHCP), you can either check the IP address assigned to the device through your router’s DHCP table or use a “arp -a” on command tool and check the IP assigned to your device MAC.

MQTT Settings

The MQTT/MQTTS Settings section allows you to configure the communication between your device and the MQTT broker. You can choose to use either MQTT (unencrypted) or MQTTS (secure, encrypted MQTT).

SettingDescriptionMandatory for MQTTMandatory for MQTTS
BrokerEnter the MQTT broker address (IP or domain) with the appropriate protocol prefix (mqtt:// or mqtts://). For example, mqtt://broker.example.com or mqtts://broker.example.com.YESYES
Publish Interval (ms)Set the publish interval in milliseconds. This defines how often the device will send data.YESYES
Client IDEnter a unique Client ID for the device. This ID is used to identify the device on the MQTT broker.YESYES
Publish TopicDefine the topic for publishing data to the broker. Devices subscribing to this topic will receive the data.YESYES
Message FormatSpecify the format of the message being sent to the broker.
For example:
1. {Relay: ~rl_val~, Digital Input: ~din_val~}. The values ~rl_val~ and ~din_val~will be replaced by the actual Relay Status and Digital Input data from the device.

2.{"relay": 0,"State":1}. This message is used to control the relay number 0 with an ON state (1).
YESYES
UsernameEnter the Username for authentication if the MQTT broker requires security.YES, If security is required.YES, If security is required.
PasswordEnter the Password for authentication if the MQTT broker requires security.YES, If security is required.YES, If security is required.
CA CertificateUpload the CA certificate used to verify the broker’s identity. This is required for secure MQTT communication (MQTTS).NOYES
Client CertificateUpload the client certificate used to authenticate the device to the broker in secure communication (MQTTS).NOYES
Client KeyUpload the client key associated with the client certificate for encrypted communication (MQTTS).NOYES

 

Important Note: After you have saved all your settings in the device settings, network settings or/and MQTT settings, the changes will only take effect after the device is rebooted. You can reboot the device either:

  • From the Webpage: Use the Reboot option in the device management section to apply all settings.
  • From the Multi-Functionality Switch: Single-click reboots the device with the new configuration set.

Additional Information

Using GPI's with switches

It is possible to read the position of a switch that is connected to a GPI. A SPST or SPDT switch is recommended to use with GPI’s. Push switches do maintain the contacts closed only for a very short time so using them is digitaltoanalog-8ethernetrelaydiscouraged. The fundamental idea of using a switch with GPI is to have the switch cause a voltage level change at the GPI pin when pressed. Usually this is achieved by using an external pull-up resistor along with the switch. The pull up resistor is connected between the GPI and VDD and the switch is connected between the GPI and ground. When the switch is not pressed, the pull-up resistor will cause the GPI to stay at the VDD voltage level. When the switch is pressed, the GPI is short-circuited to ground and stays at zero voltage. This change in voltage, and thus the position of the switch, can be read using “gpi read” command. Please see the recommended connection diagram below

Using relay modules with inductive loads

It is important to take additional care when using relays with inductive loads. An inductive load is pretty much anything that has a coil and works based on magnetic principles like Motors, Solenoids and transformers. Inductive loads produce back emf when the magnitude of the load current changes. The back emf can be in the order of tens or even hundreds of voltage (See this Wikipedia article http://en.wikipedia.org/wiki/Counter-electromotive_force). This effect is most severe when power is disconnected from inductive load because the rate of change of current is maximum at that point. Even though the back emf lives only for a very short time (a few milliseconds) it can cause sparks between the relay contacts and can deteriorate the contact quality over time and reduce the life span for the relays considerably.

So it is important to take countermeasures to suppress the back emf to acceptable levels to protect relay contacts. relay module connection details Usually this requires connecting electronic devices in parallel with the load such that they absorb the high voltage components generated by the load. For solenoids, connecting a diode (fast switching diode is recommended) in parallel to the load (in reverse direction to the load current) is very effective. A diode used for this purpose is usually called a freewheeling diode. Please see the diagram on the right for connection details.

A capacitor with proper rating is recommended for protecting the relay contacts when a motor is used as load. The capacitor should be rated enough to withstand the back emf that is generated by the motor. Please see the diagram below for connection details.relay module capacitor

Please note that the relay modules are NOT shipped with back emf suppression devices pre-installed. The exact kind of suppression device and the parameters of the selected device can vary depending on the load itself. Some of the parameters that affects the suppression device selection are the inductance of the load, power supply voltage, load current, physical size/structure of the load etc.. It is obvious that it is impossible for us to predict these parameters and design required back emf suppression device and incorporate that on the board. So we believe this is a task best left to the module user. There is an excellent article on designing back emf suppression on Wikipedia at http://en.wikipedia.org/wiki/Flyback_diode

Mechanical Dimensions

FAQ

Q. I need a customized version of this product, can Numato do the customization for me?
A. Yes, we can definitely do customization but there may be minimum order requirements depending on the level of customization required. Please write to sales@numato.com for a quote.

Q. Where can I buy this product?
A. All Numato products can be ordered directly from our web store http://www.numato.com. We accept major credit cards and Paypal and ship to almost all countries with a few exceptions. We do have distributors in many countries where you can place your order. Please find the current list of distributors here.